Like us on facebook for Air Conditioning service in Westerville OH Follow us on Twitter and let us know how pleased you are with your AC service near Lewis Center OH Find us on Google and have us service your Air Conditioning in Columbus OH Subscribe to our YouTube channel for AC repair & maintenance tips in Westerville OH Find us on yelp for great Air Conditioner repair service in Lewis Center OH

A Consumer's Guide to Lighting

Trust our technicians to deliver elite service and expertise on your furnace or AC service For AC repair in the Columbus and Central Ohio area, contact Cullins One Hour Heating and Air Conditioning today!repair, or maintenance in the Columbus and Central Ohio area.
We have certified technicians and trucks ready to handle any unit installation or replacement For Air Conditioner installation near in the Columbus and Central Ohio area, schedule service with Cullins One Hour Heating and Air Conditioning!you have in the Columbus and Central Ohio area.
Click Here to view our current sales and promotions to see how you can save on your upcoming repairCullins One Hour Heating and Air Conditioning offers coupons for your Air Conditioning repair in the Columbus and Central Ohio area!. in in the Columbus and Central Ohio area!

When to Turn Off Your Lights

The cost effectiveness of when to turn off lights depends on the type of bulb and the cost of electricity. The type of lightbulb you use is important for several reasons. All lightbulbs have a nominal or rated operating life, which is affected by how many times they are turned on and off. The more often they are switched on and off, the lower their operating life.

Incandescent Lighting

Incandescent lights should be turned off whenever they are not needed, because they are the least efficient type of lighting. 90% of the energy they use is given off as heat, and only about 10% results in light. Turning lights off will also keep a room cooler, an extra benefit in the summer.

Halogen Lighting

While halogens are more efficient than traditional incandescent bulbs, they use the same technology and are far less efficient than CFLs and LEDs. Therefore, it is best to turn these lights off whenever they are not needed.

CFL Lighting

Since they are already very efficient, the cost effectiveness of turning CFLs off to conserve energy is a bit more complicated. A general rule-of-thumb is this:

  • If you will be out of a room for 15 minutes or less, leave it on.
  • If you will be out of a room for more than 15 minutes, turn it off.

The operating life of CFLs is more affected by the number of times they are switched on and off. You can generally extend the life of a CFL bulb more by switching it on and off less frequently than if you simply use it less.

It is a popularly held belief that CFLs use a lot of energy to get started and it is better not to turn them off for short periods. The amount of energy varies between manufacturers and models—however, ENERGY STAR© rated bulbs are required to endure rapid cycling for five-minute intervals to ensure that they can hold up to frequent switching.

In any case, the relatively higher "inrush" current required lasts for half a cycle, or 1/120th of a second. The amount of electricity consumed to supply the inrush current is equal to a few seconds or less of normal light operation. Turning off fluorescent lights for more than 5 seconds will save more energy than will be consumed in turning them back on again. Therefore, the real issue is the value of the electricity saved by turning the light off relative to the cost of changing a lightbulb. This in turn determines the shortest cost-effective period for turning off a fluorescent light. 

The value of the energy saved by turning a CFL off depends on several factors: 

The price an electric utility charges its customers depends on the customer "classes," which are typically residential, commercial, and industrial. There can be different rate schedules within each class.

Some utilities may charge different rates for electricity consumption during different times of the day. It generally costs more for utilities to generate power during certain periods of high demand or consumption, called peaks.

Some utilities can charge commercial and industrial customers more per kilowatt-hour (kWh) during peak periods than for consumption off-peak.

Some utilities may also charge a base rate for a certain level of consumption and higher rates for increasing blocks of consumption.

Often a utility adds miscellaneous service charges, a base charge, and/or taxes per billing period that could be averaged per kWh consumed, if these are not already factored into the rate.

LED Lighting

The operating life of a light emitting diode (LED) is unaffected by turning it on and off. While lifetime is reduced for fluorescent lamps the more often they are switched on and off, there is no negative effect on LED lifetime. This characteristic gives LEDs several distinct advantages when it comes to operations. For example, LEDs have an advantage when used in conjunction with occupancy sensors or daylight sensors that rely on on-off operation. Also, in contrast to traditional technologies, LEDs turn on at full brightness almost instantly, with no delay. LEDs are also largely unaffected by vibration because they do not have filaments or glass enclosures.

Calculating Energy Savings

To calculate the exact value of energy savings by turning a lightbulb off, you need to first determine how much energy the bulb consumes when on. Every bulb has a watt rating printed on it. For example, if the rating is 40 watts, and the bulb is on for one hour, it will consume 0.04 kWh, or if it is off for one hour, you will be saving 0.04 kWh. (Note that many fluorescent fixtures have two or more bulbs. Also, one switch may control several fixtures—an "array." Add the savings for each fixture to determine the total energy savings.)

Then you need to find out what you are paying for electricity per kWh (in general and during peak periods). You will need to look over your electricity bills and see what the utility charges per kWh. Multiply the rate per kWh by the amount of electricity saved, and this will give you the value of the savings. Continuing with the example above, let us say that your electric rate is 10 cents per kWh. The value of the energy savings would then be 0.4 cents ($ 0.004). The value of the savings will increase the higher the watt rating of the bulb, the greater the number of bulbs controlled by a single switch, and the higher the rate per kWh.

The most cost-effective length of time that a light (or set of lights) can be turned off before the value of the savings exceeds the cost of having to replace bulbs (due to their shortened operating life) will depend on the type and model of bulb and ballast. The cost of replacing a bulb (or ballast) depends on the cost of the bulb and the cost of labor to do it.

Lighting manufacturers should be able to supply information on the duty cycle of their products. In general, the more energy-efficient a lightbulb is, the longer you can leave it on before it is cost effective to turn it off.


Source: U.S. Department of Energy

(614) 890-0851
670 Radio Dr. Lewis Center, OH 43035
Like us on facebook for AC service in Westerville OHFollow us on Twitter and let us know how pleased you are with your AC service near Lewis Center OHFind us on Google and have us service your Air Conditioning in Columbus OHSubscribe to our YouTube channel for AC repair & maintenance tips in Westerville OHFind us on yelp for great Air Conditioner repair service in Lewis Center OH