Like us on facebook for Air Conditioning service in Westerville OH Follow us on Twitter and let us know how pleased you are with your AC service near Lewis Center OH Find us on Google and have us service your Air Conditioning in Columbus OH Subscribe to our YouTube channel for AC repair & maintenance tips in Westerville OH Find us on yelp for great Air Conditioner repair service in Lewis Center OH

The Importance of GFCI

Trust our technicians to deliver elite service and expertise on your furnace or AC service For AC repair in the Columbus and Central Ohio area, contact Cullins One Hour Heating and Air Conditioning today!repair, or maintenance in the Columbus and Central Ohio area.
We have certified technicians and trucks ready to handle any unit installation or replacement For Air Conditioner installation near in the Columbus and Central Ohio area, schedule service with Cullins One Hour Heating and Air Conditioning!you have in the Columbus and Central Ohio area.
Click Here to view our current sales and promotions to see how you can save on your upcoming repairCullins One Hour Heating and Air Conditioning offers coupons for your Air Conditioning repair in the Columbus and Central Ohio area!. in in the Columbus and Central Ohio area!

Ground-Fault Circuit Interrupters (GFCI)

A ground-fault occurs when there is a break in the low-resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injuries or death. The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from equipment along the circuit conductors. When the amount going differs from the amount returning by approximately 5 milliamperes, the GFCI interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident. If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If the grounding conductor is not intact or of low-impedance, the GFCI may not trip until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful.

The GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against fires, overheating, and destruction of wire insulation.

For construction applications, there are several types of GFCIs available, with some variations:

Receptacle Type

The Receptacle Type incorporates a GFCI device within one or more receptacle outlets. Such devices are becoming popular because of their low cost.

Portable Type

Portable Type GFCIs come in several styles, all designed for easy transport. Some are designed to plug into existing non-GFCI outlets, or connect with a cord and plug arrangement. The portable type also incorporates a no-voltage release device that will disconnect power to the outlets if any supply conductor is open. Units approved for outdoor use will be in enclosures suitable for the environment. If exposed to rain, they must be listed as waterproof.

Cord-Connected Type

The Cord-Connected Type of GFCI is an attachment plug incorporating the GFCI module. It protects the cord and any equipment attached to the cord. The attachment plug has a non-standard appearance with test and reset buttons. Like the portable type, it incorporates a no-voltage release device that will disconnect power to the load if any supply conductor is open.

Because GFCIs are so complex, they require testing on a regular basis. Test permanently wired devices monthly, and portable-type GFCIs before each use. All GFCIs have a built-in test circuit, with test and reset buttons, that triggers an artificial ground-fault to verify protection. Ground-fault protection, such as GFCIs provide, is required by OSHA in addition to (not as a substitute for) general grounding requirements.


Source: U.S. Dept. of Labor Office of Safety & Health Administration


(614) 890-0851
670 Radio Dr. Lewis Center, OH 43035
Like us on facebook for AC service in Westerville OHFollow us on Twitter and let us know how pleased you are with your AC service near Lewis Center OHFind us on Google and have us service your Air Conditioning in Columbus OHSubscribe to our YouTube channel for AC repair & maintenance tips in Westerville OHFind us on yelp for great Air Conditioner repair service in Lewis Center OH